Erfahren Sie mehr
Fundo Integro

Fundo Integro

„Complying with standards, but far from standard."

The new Fundo Integro is the slimmest flush-to-floor shower element with integrated drain technology from wedi. Like all the other Fundo floor elements it is already sealed ready for installation:

  • drain capacity of 0.8 litres per second
  • 50 mm water trap height
  • at least 1.5 % even preformed gradient
  • 100 % waterproof material
The new shower element not only fulfils all relevant standards but offers an overall installation height of just 90 mm.

The Fundo Integro sets entirely new standards as a complete system – simply the perfect solution for all renovation projects, as well as a reliable and time-saving alternative for every installation. Fundo Integro - Standard-compliant complete system:
  • Complies with all common standards and guidelines: Conformity with the European DIN EN 1253 and DIN EN 12056 standards has been inspected and confirmed by an official authority.
  • Perfect for renovations: Besides 100 % compliance with standards, the Fundo Integro offers an overall installation height of just 90 mm.
  • Assured reliability: The drain technology – which is already integrated into the waterproof blue XPS core of the floor element in the factory – ensures maximum system reliability.
  • Guaranteed versatility: Alongside the stainless steel cover included in the scope of delivery, other wedi Fundo Fino designer grates can also be used – allowing further design possibilities.
  • Suitable for all tile sizes: Thanks to the flat frame, the wedi Fundo Integro can also be tiled with particularly thin ceramic or glass mosaic.

Technical properties Fundo Integro

The drain has been tested by TÜV Rheinland and fulfils all of the requirements of DIN EN 1253.


Wheelchair load-bearing from minimum tile size 50 x 50 mm
Glass mosaic (thickness: 3 mm) from minimum size 20 x 20 mm
Minimum installation height 90 mm


Technical properties of drain

Frame for the stainless steel grid (included in the scope of delivery) 120 x 120 x 4 mm
Stainless steel grid V2 A 115 x 115 x 2,5 mm
Levelling frame ø 115 x 40 mm
Drain performance DIN EN 1253-1 48 l/min; 0,8 l/s
Connection pipe (ABS) DN 50
Drain capacity in accordance with DIN EN 1253-1 50 mm
Slope connection piece 1,5 %


Technical properties of raw foam building board systems

Extruded polystyrene rigid foam core XPS
Long-term compressive strength (50 years) ≤ 2% compression EN 1606 0,08 N/mm2
Compressive resistance at 10% compression EN 826 0,25 N/mm2
Thermal conductivity EN 13164 0,036 W/mK
Bulk density EN 1602 32 kg/m3
Temperature limits -50°C / +75°C
Fire behaviour EN 13501-1 E
Waterproof tested to 1,5 bar

075900004 Floor element with fully integrated drain technology, central drain 900 × 900 × 90 mm
075900008 Floor element with fully integrated drain technology, central drain 1000 × 1000 × 90 mm
075900007 Floor element with fully integrated drain technology, central drain 1200 × 1200 × 90 mm
075900005 Floor element with fully integrated drain technology, central drain, short side connection 1200 × 900 × 90 mm
075900006 Floor element with fully integrated drain technology, central drain, long side connection 1200 × 900 × 90 mm
075900000 Floor element with fully integrated drain technology, offset drain, short side connection 1200 × 900 × 90 mm
075900001 Floor element with fully integrated drain technology, offset drain, short side connection 1400 × 900 × 90 mm
075900003 Floor element with fully integrated drain technology, offset drain, short side connection 1800 × 900 × 90 mm
075900002 Floor element with fully integrated drain technology, offset drain, short side connection 1600 × 1000 × 90 mm

wedi
In order to display YouTube videos, it is necessary that you accept marketing cookies. Please see our privacy policy for more information. To the cookie settings

Areas of application - Fundo Integro

  • In publicly accessible buildings in accordance with DIN 18040 Part 1 and DIN EN 1253
  • In accessible dwellings complying with DIN 18040 part 2 (Please see the Technical properties section for specifying the minimum tile size E.g.: for wheelchair access)
  • As structural sealing in combination with tile or slab coverings
    for load classes A0 and A.